Energy Performance Certificate

5, Spring Mews, London Road, CM21 9RE

EPC Report

Energy rating

Current: 70 C | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 70 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 Current: 70 86 Potential: 86
Field Value
LMK KEY 2018-9028-7269-3825-7930
ADDRESS1 5, Spring Mews
ADDRESS2 London Road
ADDRESS3
POSTCODE CM21 9RE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-01-29
LOCAL AUTHORITY E07000242
CONSTITUENCY E14001283
COUNTY
LODGEMENT DATE 2015-01-31
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 70
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 227
ENERGY CONSUMPTION POTENTIAL 87
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 40
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 72
LIGHTING COST POTENTIAL 38
HEATING COST CURRENT 373
HEATING COST POTENTIAL 378
HOT WATER COST CURRENT 84
HOT WATER COST POTENTIAL 54
TOTAL FLOOR AREA 51
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 10
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 10% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Spring Mews, London Road
LOCAL AUTHORITY LABEL East Hertfordshire
CONSTITUENCY LABEL Hertford and Stortford
POSTTOWN SAWBRIDGEWORTH
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2015-01-31 22:56:57
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 10033092559
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew