Energy Performance Certificate

6, Miller Close, Langstone, NP18 2LE

EPC Report

Energy rating

Current: 69 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 61 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 73 Potential: 73
Field Value
LMK KEY 2018-8093-7286-4256-4970
ADDRESS1 6, Miller Close
ADDRESS2 Langstone
ADDRESS3
POSTCODE NP18 2LE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-06-29
LOCAL AUTHORITY W06000022
CONSTITUENCY W07000104
COUNTY
LODGEMENT DATE 2016-06-29
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 177
ENERGY CONSUMPTION POTENTIAL 114
CO2 EMISSIONS CURRENT 6.9
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 4.5
LIGHTING COST CURRENT 144
LIGHTING COST POTENTIAL 104
HEATING COST CURRENT 1243
HEATING COST POTENTIAL 984
HOT WATER COST CURRENT 142
HOT WATER COST POTENTIAL 142
TOTAL FLOOR AREA 221
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 40
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 58
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 58% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, Miller Close, Langstone
LOCAL AUTHORITY LABEL Newport
CONSTITUENCY LABEL Newport East
POSTTOWN NEWPORT
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2016-06-29 18:26:05
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100100677235
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew