Energy Performance Certificate

Flat 11, 49 Shakespeare Avenue, GL2 5AH

EPC Report

Energy rating

Current: 59 D | Potential: 59 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 59 D Potential: 59 D

Environmental impact (CO₂)

Current: 57 | Potential: 57
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 57 Potential: 57
Field Value
LMK KEY 2017-1539-1112-0175-1836
ADDRESS1 Flat 11
ADDRESS2 49 Shakespeare Avenue
ADDRESS3
POSTCODE GL2 5AH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 59
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2024-03-20
LOCAL AUTHORITY E07000081
CONSTITUENCY E14001248
COUNTY
LODGEMENT DATE 2024-03-20
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 57
ENERGY CONSUMPTION CURRENT 302
ENERGY CONSUMPTION POTENTIAL 298
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 53
CO2 EMISSIONS POTENTIAL 3
LIGHTING COST CURRENT 112
LIGHTING COST POTENTIAL 84
HEATING COST CURRENT 1082
HEATING COST POTENTIAL 1086
HOT WATER COST CURRENT 171
HOT WATER COST POTENTIAL 171
TOTAL FLOOR AREA 58
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 4.13
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 11, 49 Shakespeare Avenue
LOCAL AUTHORITY LABEL Gloucester
CONSTITUENCY LABEL Gloucester
POSTTOWN GLOUCESTER
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2024-03-20 12:17:03
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100120500214
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000009
Address display
Nation ew