Energy Performance Certificate

250 Howard Road, IG11 7DP

EPC Report

Energy rating

Current: 75 C | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 71 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 Current: 71 76 Potential: 76
Field Value
LMK KEY 2017-1311-1901-3131-2497
ADDRESS1 250 Howard Road
ADDRESS2
ADDRESS3
POSTCODE IG11 7DP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-12-08
LOCAL AUTHORITY E09000002
CONSTITUENCY E14001073
COUNTY
LODGEMENT DATE 2021-12-17
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 71
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 174
ENERGY CONSUMPTION POTENTIAL 139
CO2 EMISSIONS CURRENT 1.8
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 56
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 430
HEATING COST POTENTIAL 402
HOT WATER COST CURRENT 85
HOT WATER COST POTENTIAL 58
TOTAL FLOOR AREA 58
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 89
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 89% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.77
PHOTO SUPPLY 40
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 250 Howard Road
LOCAL AUTHORITY LABEL Barking and Dagenham
CONSTITUENCY LABEL Barking
POSTTOWN BARKING
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2021-12-17 00:24:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100057370
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000007
Address display
Nation ew