Energy Performance Certificate

52 London Road, RG1 5AS

EPC Report

Energy rating

Current: 52 E | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 35 | Potential: 62
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 Current: 35 62 Potential: 62
Field Value
LMK KEY 2013-7690-3908-0161-5313
ADDRESS1 52 London Road
ADDRESS2
ADDRESS3
POSTCODE RG1 5AS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2023-09-28
LOCAL AUTHORITY E06000038
CONSTITUENCY E14001438
COUNTY
LODGEMENT DATE 2023-11-03
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 35
ENVIRONMENT IMPACT POTENTIAL 62
ENERGY CONSUMPTION CURRENT 260
ENERGY CONSUMPTION POTENTIAL 125
CO2 EMISSIONS CURRENT 15
CO2 EMISS CURR PER FLOOR AREA 56
CO2 EMISSIONS POTENTIAL 7.4
LIGHTING COST CURRENT 263
LIGHTING COST POTENTIAL 267
HEATING COST CURRENT 5256
HEATING COST POTENTIAL 2778
HOT WATER COST CURRENT 382
HOT WATER COST POTENTIAL 384
TOTAL FLOOR AREA 272
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 4
MAIN HEATING CONTROLS Programmer and at least two room thermostats
MULTI GLAZE PROPORTION 40
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 6
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial secondary glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, smokeless fuel
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and at least two room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.16
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 52 London Road
LOCAL AUTHORITY LABEL Reading
CONSTITUENCY LABEL Reading Central
POSTTOWN READING
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2023-11-03 14:38:27
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 27
LOW ENERGY FIXED LIGHT COUNT 27
UPRN 310053490
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000008
Address display
Nation ew