Energy Performance Certificate

5 Harlyn Road, SO16 4NG

EPC Report

Energy rating

Current: 66 D | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 D Current: 66 D 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 84 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 Current: 84 90 Potential: 90
Field Value
LMK KEY 2012-6265-8178-1458-2882
ADDRESS1 5 Harlyn Road
ADDRESS2
ADDRESS3
POSTCODE SO16 4NG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 66
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2026-02-23
LOCAL AUTHORITY E06000045
CONSTITUENCY E14001500
COUNTY
LODGEMENT DATE 2026-02-23
TRANSACTION TYPE Re-mortgaging
ENVIRONMENT IMPACT CURRENT 84
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 114
ENERGY CONSUMPTION POTENTIAL 61
CO2 EMISSIONS CURRENT 1.3
CO2 EMISS CURR PER FLOOR AREA 17
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 53
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 1184
HEATING COST POTENTIAL 789
HOT WATER COST CURRENT 196
HOT WATER COST POTENTIAL 198
TOTAL FLOOR AREA 75
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5 Harlyn Road
LOCAL AUTHORITY LABEL Southampton
CONSTITUENCY LABEL Southampton Test
POSTTOWN SOUTHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2026-02-23 21:48:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 18
UPRN 100060702450