Energy Performance Certificate

3 Linden Park House, 7A Linden Park Road, TN2 5QL

EPC Report

Energy rating

Current: 87 B | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 87 B Current: 87 B 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 91 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 91 Current: 91 91 Potential: 91
Field Value
LMK KEY 2003-3008-8306-7824-0200
ADDRESS1 3 Linden Park House
ADDRESS2 7A Linden Park Road
ADDRESS3
POSTCODE TN2 5QL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 87
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2024-06-20
LOCAL AUTHORITY E07000116
CONSTITUENCY E14001555
COUNTY
LODGEMENT DATE 2024-06-20
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 91
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 58
ENERGY CONSUMPTION POTENTIAL 58
CO2 EMISSIONS CURRENT 0.9
CO2 EMISS CURR PER FLOOR AREA 10.1
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 58
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 192
HEATING COST POTENTIAL 192
HOT WATER COST CURRENT 152
HOT WATER COST POTENTIAL 152
TOTAL FLOOR AREA 84
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.15 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 3 Linden Park House, 7A Linden Park Road
LOCAL AUTHORITY LABEL Tunbridge Wells
CONSTITUENCY LABEL Tunbridge Wells
POSTTOWN Tunbridge Wells
CONSTRUCTION AGE BAND 2022
LODGEMENT DATETIME 2024-06-20 11:21:25
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 100061207056
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew