Energy Performance Certificate

90 Coleridge Drive, RUISLIP, HA4 8GW

EPC Report

Energy rating

Current: 78 C | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 C Current: 78 C 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 88 | Potential: 97
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 Current: 88 97 Potential: 97
Field Value
LMK KEY 2001-7387-5070-4209-6201
ADDRESS1 90 Coleridge Drive
ADDRESS2
ADDRESS3 RUISLIP
POSTCODE HA4 8GW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 78
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2023-03-06
LOCAL AUTHORITY E09000017
CONSTITUENCY E14001454
COUNTY
LODGEMENT DATE 2023-03-16
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 88
ENVIRONMENT IMPACT POTENTIAL 97
ENERGY CONSUMPTION CURRENT 115
ENERGY CONSUMPTION POTENTIAL 47
CO2 EMISSIONS CURRENT 1.2
CO2 EMISS CURR PER FLOOR AREA 12
CO2 EMISSIONS POTENTIAL 0.1
LIGHTING COST CURRENT 115
LIGHTING COST POTENTIAL 115
HEATING COST CURRENT 350
HEATING COST POTENTIAL 349
HOT WATER COST CURRENT 118
HOT WATER COST POTENTIAL 87
TOTAL FLOOR AREA 97
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 90 Coleridge Drive, RUISLIP
LOCAL AUTHORITY LABEL Hillingdon
CONSTITUENCY LABEL Ruislip, Northwood and Pinner
POSTTOWN
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2023-03-16 19:54:27
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 10022805349
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000007
Address display
Nation ew