Energy Performance Certificate

18 Dalton Crescent, DH1 4FB

EPC Report

Energy rating

Current: 72 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 76 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 78 Potential: 78
Field Value
LMK KEY 2001-6409-9050-1190-6005
ADDRESS1 18 Dalton Crescent
ADDRESS2
ADDRESS3
POSTCODE DH1 4FB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-11-06
LOCAL AUTHORITY E06000047
CONSTITUENCY E14001173
COUNTY
LODGEMENT DATE 2025-11-12
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 130
ENERGY CONSUMPTION POTENTIAL 117
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 22
CO2 EMISSIONS POTENTIAL 2.9
LIGHTING COST CURRENT 181
LIGHTING COST POTENTIAL 115
HEATING COST CURRENT 1089
HEATING COST POTENTIAL 1101
HOT WATER COST CURRENT 230
HOT WATER COST POTENTIAL 229
TOTAL FLOOR AREA 139
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 53
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.296
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 18 Dalton Crescent
LOCAL AUTHORITY LABEL County Durham
CONSTITUENCY LABEL City of Durham
POSTTOWN DURHAM
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2025-11-12 16:22:45
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 64
LOW ENERGY FIXED LIGHT COUNT 34
UPRN 10001009410
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000001
Address display
Nation ew