Energy Performance Certificate

57 Swaythling Close, N18 2QG

EPC Report

Energy rating

Current: 76 C | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 64 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 70 Potential: 70
Field Value
LMK KEY 2000-5409-7290-2790-6025
ADDRESS1 57 Swaythling Close
ADDRESS2
ADDRESS3
POSTCODE N18 2QG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-11-26
LOCAL AUTHORITY E09000010
CONSTITUENCY E14001221
COUNTY
LODGEMENT DATE 2021-11-30
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 351
ENERGY CONSUMPTION POTENTIAL 293
CO2 EMISSIONS CURRENT 1.8
CO2 EMISS CURR PER FLOOR AREA 59
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 65
LIGHTING COST POTENTIAL 32
HEATING COST CURRENT 177
HEATING COST POTENTIAL 124
HOT WATER COST CURRENT 153
HOT WATER COST POTENTIAL 153
TOTAL FLOOR AREA 30
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 4.75
FLOOR HEIGHT 2.32
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 57 Swaythling Close
LOCAL AUTHORITY LABEL Enfield
CONSTITUENCY LABEL Edmonton and Winchmore Hill
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2021-11-30 16:25:15
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 207007420
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000007
Address display
Nation ew