Energy Performance Certificate

135 Winskell Road, NE34 9RY

EPC Report

Energy rating

Current: 74 C | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 77 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 79 Potential: 79
Field Value
LMK KEY 2000-5306-2160-2305-2091
ADDRESS1 135 Winskell Road
ADDRESS2
ADDRESS3
POSTCODE NE34 9RY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 74
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE Bungalow
BUILT FORM Mid-Terrace
INSPECTION DATE 2026-06-12
LOCAL AUTHORITY E08000023
CONSTITUENCY E14001492
COUNTY
LODGEMENT DATE 2026-06-12
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 165
ENERGY CONSUMPTION POTENTIAL 139
CO2 EMISSIONS CURRENT 1.9
CO2 EMISS CURR PER FLOOR AREA 30
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 49
HEATING COST CURRENT 611
HEATING COST POTENTIAL 617
HOT WATER COST CURRENT 189
HOT WATER COST POTENTIAL 189
TOTAL FLOOR AREA 65
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 225 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 135 Winskell Road
LOCAL AUTHORITY LABEL South Tyneside
CONSTITUENCY LABEL South Shields
POSTTOWN SOUTH SHIELDS
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2026-06-12 15:01:34
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 103002325
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000001
Address display
Nation ew