Energy Performance Certificate

164 Trowbridge Green, Trowbridge, CF3 1RD

EPC Report

Energy rating

Current: 76 C | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 76 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 88 Potential: 88
Field Value
LMK KEY 1908-3835-0002-1992-0502
ADDRESS1 164 Trowbridge Green
ADDRESS2 Trowbridge
ADDRESS3
POSTCODE CF3 1RD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2025-02-11
LOCAL AUTHORITY W06000015
CONSTITUENCY W07000089
COUNTY
LODGEMENT DATE 2025-04-21
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 140
ENERGY CONSUMPTION POTENTIAL 51
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 25
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 126
LIGHTING COST POTENTIAL 98
HEATING COST CURRENT 528
HEATING COST POTENTIAL 495
HOT WATER COST CURRENT 117
HOT WATER COST POTENTIAL 73
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 164 Trowbridge Green, Trowbridge
LOCAL AUTHORITY LABEL Cardiff
CONSTITUENCY LABEL Cardiff East
POSTTOWN Cardiff
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2025-04-21 19:08:56
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10008903158
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY Wales
REGION W99999999
Address display