Energy Performance Certificate

Flat 3, 164 High Street, SO14 2BT

EPC Report

Energy rating

Current: 63 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 67 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 Current: 67 65 Potential: 65
Field Value
LMK KEY 1737-6328-3200-0580-5276
ADDRESS1 Flat 3
ADDRESS2 164 High Street
ADDRESS3
POSTCODE SO14 2BT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-08-30
LOCAL AUTHORITY E06000045
CONSTITUENCY E14001499
COUNTY
LODGEMENT DATE 2023-08-30
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 67
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 318
ENERGY CONSUMPTION POTENTIAL 336
CO2 EMISSIONS CURRENT 1.6
CO2 EMISS CURR PER FLOOR AREA 54
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 75
LIGHTING COST POTENTIAL 93
HEATING COST CURRENT 564
HEATING COST POTENTIAL 238
HOT WATER COST CURRENT 517
HOT WATER COST POTENTIAL 201
TOTAL FLOOR AREA 30
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Full secondary glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 0.88
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 3, 164 High Street
LOCAL AUTHORITY LABEL Southampton
CONSTITUENCY LABEL Southampton Itchen
POSTTOWN SOUTHAMPTON
CONSTRUCTION AGE BAND England and Wales: 2012 onwards
LODGEMENT DATETIME 2023-08-30 20:46:29
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10024439497
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000008
Address display
Nation ew