Energy Performance Certificate

3 Parham Close, Hintlesham, IP8 3GP

EPC Report

Energy rating

Current: 83 B | Potential: 119 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 B Current: 83 B 119 A Potential: 119 A

Environmental impact (CO₂)

Current: 85 | Potential: 117
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 Current: 85 117 Potential: 117
Field Value
LMK KEY 1737-4331-5000-0553-6206
ADDRESS1 3 Parham Close
ADDRESS2 Hintlesham
ADDRESS3
POSTCODE IP8 3GP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 83
POTENTIAL ENERGY EFFICIENCY 119
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2023-09-07
LOCAL AUTHORITY E07000200
CONSTITUENCY E14001494
COUNTY
LODGEMENT DATE 2023-09-07
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 85
ENVIRONMENT IMPACT POTENTIAL 117
ENERGY CONSUMPTION CURRENT 99
ENERGY CONSUMPTION POTENTIAL -130
CO2 EMISSIONS CURRENT 1.3
CO2 EMISS CURR PER FLOOR AREA 17
CO2 EMISSIONS POTENTIAL -1.8
LIGHTING COST CURRENT 132
LIGHTING COST POTENTIAL 132
HEATING COST CURRENT 363
HEATING COST POTENTIAL 364
HOT WATER COST CURRENT 450
HOT WATER COST POTENTIAL 268
TOTAL FLOOR AREA 80
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.12 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.21 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 3 Parham Close, Hintlesham
LOCAL AUTHORITY LABEL Babergh
CONSTITUENCY LABEL South Suffolk
POSTTOWN Ipswich
CONSTRUCTION AGE BAND 2020
LODGEMENT DATETIME 2023-09-07 13:46:52
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 10094143014
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2023.csv
COUNTRY England
REGION E12000006
Address display
Nation ew