Energy Performance Certificate

39 Water End, Eversholt, MK17 9EA

EPC Report

Energy rating

Current: 33 F | Potential: 62 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 F Current: 33 F 62 D Potential: 62 D

Environmental impact (CO₂)

Current: 81 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 Current: 81 89 Potential: 89
Field Value
LMK KEY 1735-3826-1500-0156-1292
ADDRESS1 39 Water End
ADDRESS2 Eversholt
ADDRESS3
POSTCODE MK17 9EA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 33
POTENTIAL ENERGY EFFICIENCY 62
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-06-16
LOCAL AUTHORITY E06000056
CONSTITUENCY E14001359
COUNTY
LODGEMENT DATE 2025-06-17
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 81
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 230
ENERGY CONSUMPTION POTENTIAL 138
CO2 EMISSIONS CURRENT 1.6
CO2 EMISS CURR PER FLOOR AREA 22
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 54
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 1928
HEATING COST POTENTIAL 1423
HOT WATER COST CURRENT 708
HOT WATER COST POTENTIAL 416
TOTAL FLOOR AREA 73
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 96
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 85
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly multiple glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric underfloor heating
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 39 Water End, Eversholt
LOCAL AUTHORITY LABEL Central Bedfordshire
CONSTITUENCY LABEL Mid Bedfordshire
POSTTOWN MILTON KEYNES
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2025-06-17 18:02:23
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 26
LOW ENERGY FIXED LIGHT COUNT 22
UPRN 10000799439
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000006
Address display
Nation ew