Energy Performance Certificate

99 Sandon Road, B17 8EE

EPC Report

Energy rating

Current: 35 F | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 13 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 13 Current: 13 72 Potential: 72
Field Value
LMK KEY 1637-6523-8200-0554-8296
ADDRESS1 99 Sandon Road
ADDRESS2
ADDRESS3
POSTCODE B17 8EE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2023-07-14
LOCAL AUTHORITY E08000025
CONSTITUENCY E14001092
COUNTY
LODGEMENT DATE 2023-07-31
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 13
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 648
ENERGY CONSUMPTION POTENTIAL 141
CO2 EMISSIONS CURRENT 22
CO2 EMISS CURR PER FLOOR AREA 110
CO2 EMISSIONS POTENTIAL 5.1
LIGHTING COST CURRENT 471
LIGHTING COST POTENTIAL 224
HEATING COST CURRENT 5506
HEATING COST POTENTIAL 2509
HOT WATER COST CURRENT 275
HOT WATER COST POTENTIAL 280
TOTAL FLOOR AREA 202
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 71
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 32
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 32% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.75
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 99 Sandon Road
LOCAL AUTHORITY LABEL Birmingham
CONSTITUENCY LABEL Birmingham Edgbaston
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2023-07-31 22:41:55
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100070503660
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000005
Address display
Nation ew