Energy Performance Certificate

23 Coaching Walk, NN3 3EU

EPC Report

Energy rating

Current: 61 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 53 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 72 Potential: 72
Field Value
LMK KEY 1600-4534-0722-5406-3253
ADDRESS1 23 Coaching Walk
ADDRESS2
ADDRESS3
POSTCODE NN3 3EU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2025-02-07
LOCAL AUTHORITY E06000062
CONSTITUENCY E14001406
COUNTY
LODGEMENT DATE 2025-02-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 270
ENERGY CONSUMPTION POTENTIAL 153
CO2 EMISSIONS CURRENT 5.3
CO2 EMISS CURR PER FLOOR AREA 49
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 108
LIGHTING COST POTENTIAL 108
HEATING COST CURRENT 1400
HEATING COST POTENTIAL 1097
HOT WATER COST CURRENT 152
HOT WATER COST POTENTIAL 104
TOTAL FLOOR AREA 109
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS TRVs and bypass
MULTI GLAZE PROPORTION 95
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 97
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 97% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23 Coaching Walk
LOCAL AUTHORITY LABEL West Northamptonshire
CONSTITUENCY LABEL Northampton North
POSTTOWN NORTHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2025-02-07 19:20:02
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 34
LOW ENERGY FIXED LIGHT COUNT 33
UPRN 15019775
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000004
Address display
Nation ew