Energy Performance Certificate

Dunroamin, Layer Breton Hill, Layer Breton, CO2 0PR

EPC Report

Energy rating

Current: 1 G | Potential: 37 F
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 37 F Potential: 37 F

Environmental impact (CO₂)

Current: 3 | Potential: 15
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 3 Current: 3 15 Potential: 15
Field Value
LMK KEY 1534-6429-4309-0505-8292
ADDRESS1 Dunroamin
ADDRESS2 Layer Breton Hill
ADDRESS3 Layer Breton
POSTCODE CO2 0PR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING F
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 37
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2024-11-15
LOCAL AUTHORITY E07000071
CONSTITUENCY E14001590
COUNTY
LODGEMENT DATE 2024-11-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 3
ENVIRONMENT IMPACT POTENTIAL 15
ENERGY CONSUMPTION CURRENT 1005
ENERGY CONSUMPTION POTENTIAL 756
CO2 EMISSIONS CURRENT 13
CO2 EMISS CURR PER FLOOR AREA 175
CO2 EMISSIONS POTENTIAL 9.9
LIGHTING COST CURRENT 153
LIGHTING COST POTENTIAL 175
HEATING COST CURRENT 5438
HEATING COST POTENTIAL 2706
HOT WATER COST CURRENT 654
HOT WATER COST POTENTIAL 240
TOTAL FLOOR AREA 76
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION Solid fuel boiler/circulator, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Dunroamin, Layer Breton Hill, Layer Breton
LOCAL AUTHORITY LABEL Colchester
CONSTITUENCY LABEL Witham
POSTTOWN COLCHESTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2024-11-15 12:42:50
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100091467214
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000006
Address display
Nation ew