Energy Performance Certificate

199 The Keep, KT2 5UG

EPC Report

Energy rating

Current: 62 D | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 60 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 Current: 60 70 Potential: 70
Field Value
LMK KEY 1237-8628-0200-0102-9226
ADDRESS1 199 The Keep
ADDRESS2
ADDRESS3
POSTCODE KT2 5UG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE Maisonette
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2023-08-22
LOCAL AUTHORITY E09000021
CONSTITUENCY E14001445
COUNTY
LODGEMENT DATE 2023-08-22
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 60
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 217
ENERGY CONSUMPTION POTENTIAL 161
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 38
CO2 EMISSIONS POTENTIAL 2.8
LIGHTING COST CURRENT 197
LIGHTING COST POTENTIAL 197
HEATING COST CURRENT 1690
HEATING COST POTENTIAL 1140
HOT WATER COST CURRENT 356
HOT WATER COST POTENTIAL 359
TOTAL FLOOR AREA 99
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 3.52
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 199 The Keep
LOCAL AUTHORITY LABEL Kingston upon Thames
CONSTITUENCY LABEL Richmond Park
POSTTOWN KINGSTON UPON THAMES
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2023-08-22 18:41:04
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 100023058313
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000007
Address display
Nation ew