Energy Performance Certificate

80 GOFFSMILL, BRETTON, PETERBOROUGH, PE3 9YW

EPC Report

Energy rating

Current: 74 C | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 75 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 82 Potential: 82
Field Value
LMK KEY 1190-3108-0122-4073-3003
ADDRESS1 80 GOFFSMILL
ADDRESS2 BRETTON
ADDRESS3 PETERBOROUGH
POSTCODE PE3 9YW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 74
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2020-10-30
LOCAL AUTHORITY E06000031
CONSTITUENCY E14001425
COUNTY
LODGEMENT DATE 2020-10-30
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 75
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 179
ENERGY CONSUMPTION POTENTIAL 130
CO2 EMISSIONS CURRENT 1.9
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 72
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 340
HEATING COST POTENTIAL 254
HOT WATER COST CURRENT 75
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 60
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 1
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 80 GOFFSMILL, BRETTON, PETERBOROUGH
LOCAL AUTHORITY LABEL Peterborough
CONSTITUENCY LABEL Peterborough
POSTTOWN PETERBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2020-10-30 14:58:29
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100090195961
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000006
Address display
Nation ew