Energy Performance Certificate

145a, Putney High Street, SW15 1SU

EPC Report

Energy rating

Current: 46 E | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 32 | Potential: 54
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 54 Potential: 54
Field Value
LMK KEY 1090-3537-0022-1007-3903
ADDRESS1 145a, Putney High Street
ADDRESS2
ADDRESS3
POSTCODE SW15 1SU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE Maisonette
BUILT FORM Mid-Terrace
INSPECTION DATE 2020-11-07
LOCAL AUTHORITY E09000032
CONSTITUENCY E14001434
COUNTY
LODGEMENT DATE 2020-11-12
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 54
ENERGY CONSUMPTION CURRENT 437
ENERGY CONSUMPTION POTENTIAL 253
CO2 EMISSIONS CURRENT 7.3
CO2 EMISS CURR PER FLOOR AREA 74
CO2 EMISSIONS POTENTIAL 4.2
LIGHTING COST CURRENT 128
LIGHTING COST POTENTIAL 89
HEATING COST CURRENT 1188
HEATING COST POTENTIAL 545
HOT WATER COST CURRENT 375
HOT WATER COST POTENTIAL 204
TOTAL FLOOR AREA 98
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 57
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 55
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial secondary glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 55% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 145a, Putney High Street
LOCAL AUTHORITY LABEL Wandsworth
CONSTITUENCY LABEL Putney
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2020-11-12 15:02:53
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 6
UPRN
UPRN SOURCE
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000007
Address display
Nation ew