Energy Performance Certificate

17 DARNLEY ROAD, GRAVESEND, DA11 0RZ

EPC Report

Energy rating

Current: 1 G | Potential: 68 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 68 D Potential: 68 D

Environmental impact (CO₂)

Current: 1 | Potential: 96
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 Current: 1 96 Potential: 96
Field Value
LMK KEY 1039-6627-6000-0176-4296
ADDRESS1 17 DARNLEY ROAD
ADDRESS2 GRAVESEND
ADDRESS3
POSTCODE DA11 0RZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 68
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-03-16
LOCAL AUTHORITY E07000109
CONSTITUENCY E14001254
COUNTY
LODGEMENT DATE 2021-03-17
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 1
ENVIRONMENT IMPACT POTENTIAL 96
ENERGY CONSUMPTION CURRENT 806
ENERGY CONSUMPTION POTENTIAL 131
CO2 EMISSIONS CURRENT 50
CO2 EMISS CURR PER FLOOR AREA 269
CO2 EMISSIONS POTENTIAL 0.5
LIGHTING COST CURRENT 185
LIGHTING COST POTENTIAL 189
HEATING COST CURRENT 6130
HEATING COST POTENTIAL 1069
HOT WATER COST CURRENT 279
HOT WATER COST POTENTIAL 120
TOTAL FLOOR AREA 184
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 4
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 5
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 29
NUMBER OPEN FIREPLACES 5
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, smokeless fuel
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 29% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL smokeless coal
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 17 DARNLEY ROAD, GRAVESEND
LOCAL AUTHORITY LABEL Gravesham
CONSTITUENCY LABEL Gravesham
POSTTOWN GRAVESEND
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-03-17 20:24:30
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100060926379
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew