Energy Performance Certificate

7 Ebor House, Ferndale Terrace, YO15 3AU

EPC Report

Energy rating

Current: 81 B | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 B Current: 81 B 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 68 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 Current: 68 73 Potential: 73
Field Value
LMK KEY 1034-6928-6300-0489-2226
ADDRESS1 7 Ebor House
ADDRESS2 Ferndale Terrace
ADDRESS3
POSTCODE YO15 3AU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 81
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-08-21
LOCAL AUTHORITY E06000011
CONSTITUENCY E14001127
COUNTY
LODGEMENT DATE 2024-08-23
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 68
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 243
ENERGY CONSUMPTION POTENTIAL 207
CO2 EMISSIONS CURRENT 2.6
CO2 EMISS CURR PER FLOOR AREA 41
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 99
LIGHTING COST POTENTIAL 99
HEATING COST CURRENT 228
HEATING COST POTENTIAL 281
HOT WATER COST CURRENT 514
HOT WATER COST POTENTIAL 352
TOTAL FLOOR AREA 63
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, with external insulation
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters, Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 7.51
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7 Ebor House, Ferndale Terrace
LOCAL AUTHORITY LABEL East Riding of Yorkshire
CONSTITUENCY LABEL Bridlington and The Wolds
POSTTOWN BRIDLINGTON
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2024-08-23 14:20:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100050019420
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000003
Address display
Nation ew