Energy Performance Certificate

31 PASTEUR CLOSE, COLINDALE, LONDON, NW9 5HQ

EPC Report

Energy rating

Current: 69 C | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 51 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 70 Potential: 70
Field Value
LMK KEY 1000-5089-0022-4222-0103
ADDRESS1 31 PASTEUR CLOSE
ADDRESS2 COLINDALE
ADDRESS3 LONDON
POSTCODE NW9 5HQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2020-09-28
LOCAL AUTHORITY E09000003
CONSTITUENCY E14001279
COUNTY
LODGEMENT DATE 2020-09-30
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 362
ENERGY CONSUMPTION POTENTIAL 221
CO2 EMISSIONS CURRENT 3.2
CO2 EMISS CURR PER FLOOR AREA 61
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 53
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 439
HEATING COST POTENTIAL 215
HOT WATER COST CURRENT 195
HOT WATER COST POTENTIAL 146
TOTAL FLOOR AREA 53
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 6.2
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31 PASTEUR CLOSE, COLINDALE, LONDON
LOCAL AUTHORITY LABEL Barnet
CONSTITUENCY LABEL Hendon
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2020-09-30 20:29:11
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 200092170
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000007
Address display
Nation ew