Energy Performance Certificate

38, Ledbury Road, BS16 4AG

EPC Report

Energy rating

Current: 40 E | Potential: 41 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 41 E Potential: 41 E

Environmental impact (CO₂)

Current: 40 | Potential: 41
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 41 Potential: 41
Field Value
LMK KEY 0988-1007-7221-3385-8930
ADDRESS1 38, Ledbury Road
ADDRESS2
ADDRESS3
POSTCODE BS16 4AG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 41
PROPERTY TYPE Maisonette
BUILT FORM End-Terrace
INSPECTION DATE 2015-09-08
LOCAL AUTHORITY E06000023
CONSTITUENCY E14001133
COUNTY
LODGEMENT DATE 2015-12-05
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 41
ENERGY CONSUMPTION CURRENT 437
ENERGY CONSUMPTION POTENTIAL 429
CO2 EMISSIONS CURRENT 5.1
CO2 EMISS CURR PER FLOOR AREA 77
CO2 EMISSIONS POTENTIAL 5.0
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 694
HEATING COST POTENTIAL 699
HOT WATER COST CURRENT 496
HOT WATER COST POTENTIAL 496
TOTAL FLOOR AREA 66
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Flat rate charging, no thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 29
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Flat rate charging, no thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 29% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 2.67
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 38, Ledbury Road
LOCAL AUTHORITY LABEL Bristol, City of
CONSTITUENCY LABEL Bristol North East
POSTTOWN BRISTOL
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-12-05 21:13:26
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 48453
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000009
Address display
Nation ew