Energy Performance Certificate

12 Craigside Drive, LL30 3BE

EPC Report

Energy rating

Current: 47 E | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 E Current: 47 E 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 37 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 Current: 37 67 Potential: 67
Field Value
LMK KEY 0986-0200-0204-1701-0554
ADDRESS1 12 Craigside Drive
ADDRESS2
ADDRESS3
POSTCODE LL30 3BE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 47
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2024-08-13
LOCAL AUTHORITY W06000003
CONSTITUENCY W07000083
COUNTY
LODGEMENT DATE 2024-08-13
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 37
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 327
ENERGY CONSUMPTION POTENTIAL 150
CO2 EMISSIONS CURRENT 17.3
CO2 EMISS CURR PER FLOOR AREA 60
CO2 EMISSIONS POTENTIAL 8.1
LIGHTING COST CURRENT 255
LIGHTING COST POTENTIAL 255
HEATING COST CURRENT 5292
HEATING COST POTENTIAL 2956
HOT WATER COST CURRENT 750
HOT WATER COST POTENTIAL 228
TOTAL FLOOR AREA 290
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 86
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 86
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas, Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 86% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12 Craigside Drive
LOCAL AUTHORITY LABEL Conwy
CONSTITUENCY LABEL Bangor Aberconwy
POSTTOWN LLANDUDNO
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2024-08-13 17:27:24
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 28
LOW ENERGY FIXED LIGHT COUNT 24
UPRN 50000010651
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew