Energy Performance Certificate

1, Bristol Road, DN17 1TZ

EPC Report

Energy rating

Current: 50 E | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 E Current: 50 E 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 40 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 75 Potential: 75
Field Value
LMK KEY 0980-2881-6890-9705-4325
ADDRESS1 1, Bristol Road
ADDRESS2
ADDRESS3
POSTCODE DN17 1TZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 50
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-01-09
LOCAL AUTHORITY E06000013
CONSTITUENCY E14001462
COUNTY
LODGEMENT DATE 2015-01-15
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 326
ENERGY CONSUMPTION POTENTIAL 123
CO2 EMISSIONS CURRENT 13
CO2 EMISS CURR PER FLOOR AREA 58
CO2 EMISSIONS POTENTIAL 4.8
LIGHTING COST CURRENT 137
LIGHTING COST POTENTIAL 91
HEATING COST CURRENT 2771
HEATING COST POTENTIAL 1218
HOT WATER COST CURRENT 210
HOT WATER COST POTENTIAL 127
TOTAL FLOOR AREA 219
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Bristol Road
LOCAL AUTHORITY LABEL North Lincolnshire
CONSTITUENCY LABEL Scunthorpe
POSTTOWN SCUNTHORPE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2015-01-15 11:32:42
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 32
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 100050197410
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000003
Address display
Nation ew