Energy Performance Certificate

12, Maes Terfyn, Morfa Nefyn, LL53 6EQ

EPC Report

Energy rating

Current: 75 C | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 68 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 Current: 68 83 Potential: 83
Field Value
LMK KEY 0968-9987-7279-1867-0944
ADDRESS1 12, Maes Terfyn
ADDRESS2 Morfa Nefyn
ADDRESS3
POSTCODE LL53 6EQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2013-11-06
LOCAL AUTHORITY W06000002
CONSTITUENCY W07000096
COUNTY
LODGEMENT DATE 2013-11-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 68
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 124
ENERGY CONSUMPTION POTENTIAL 50
CO2 EMISSIONS CURRENT 4.2
CO2 EMISS CURR PER FLOOR AREA 30
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 134
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 622
HEATING COST POTENTIAL 550
HOT WATER COST CURRENT 161
HOT WATER COST POTENTIAL 112
TOTAL FLOOR AREA 141
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 12
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 12% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12, Maes Terfyn, Morfa Nefyn
LOCAL AUTHORITY LABEL Gwynedd
CONSTITUENCY LABEL Dwyfor Meirionnydd
POSTTOWN PWLLHELI
CONSTRUCTION AGE BAND England and Wales: 2007 onwards
LODGEMENT DATETIME 2013-11-06 22:24:15
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 10024261649
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew