Energy Performance Certificate

Flat 2, 59a High Street, Wealdstone, HA3 5DQ

EPC Report

Energy rating

Current: 24 F | Potential: 52 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 24 F Current: 24 F 52 E Potential: 52 E

Environmental impact (CO₂)

Current: 33 | Potential: 39
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 39 Potential: 39
Field Value
LMK KEY 0968-3067-7201-4776-0990
ADDRESS1 Flat 2
ADDRESS2 59a High Street
ADDRESS3 Wealdstone
POSTCODE HA3 5DQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 24
POTENTIAL ENERGY EFFICIENCY 52
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-09-06
LOCAL AUTHORITY E09000015
CONSTITUENCY E14001271
COUNTY
LODGEMENT DATE 2016-09-07
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 39
ENERGY CONSUMPTION CURRENT 987
ENERGY CONSUMPTION POTENTIAL 852
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 169
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 23
LIGHTING COST POTENTIAL 25
HEATING COST CURRENT 785
HEATING COST POTENTIAL 365
HOT WATER COST CURRENT 189
HOT WATER COST POTENTIAL 189
TOTAL FLOOR AREA 21
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 2, 59a High Street, Wealdstone
LOCAL AUTHORITY LABEL Harrow
CONSTITUENCY LABEL Harrow West
POSTTOWN HARROW
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2016-09-07 22:26:32
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10094043294
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000007
Address display
Nation ew