Energy Performance Certificate

37 Parade Court, BS5 7TB

EPC Report

Energy rating

Current: 75 C | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 79 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 Current: 79 83 Potential: 83
Field Value
LMK KEY 0960-0200-0505-8821-0100
ADDRESS1 37 Parade Court
ADDRESS2
ADDRESS3
POSTCODE BS5 7TB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2025-06-18
LOCAL AUTHORITY E06000023
CONSTITUENCY E14001133
COUNTY
LODGEMENT DATE 2025-06-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 79
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 151
ENERGY CONSUMPTION POTENTIAL 120
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 27
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 49
LIGHTING COST POTENTIAL 49
HEATING COST CURRENT 339
HEATING COST POTENTIAL 297
HOT WATER COST CURRENT 167
HOT WATER COST POTENTIAL 123
TOTAL FLOOR AREA 51
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 82
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR stairwell
UNHEATED CORRIDOR LENGTH 4.999
FLOOR HEIGHT 2.22
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 37 Parade Court
LOCAL AUTHORITY LABEL Bristol, City of
CONSTITUENCY LABEL Bristol North East
POSTTOWN BRISTOL
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2025-06-18 12:38:22
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 280011
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000009
Address display
Nation ew