Energy Performance Certificate

22, Botany Road, Eccles, M30 8JS

EPC Report

Energy rating

Current: 64 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 58 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 Current: 58 72 Potential: 72
Field Value
LMK KEY 0958-4097-7234-4236-7990
ADDRESS1 22, Botany Road
ADDRESS2 Eccles
ADDRESS3
POSTCODE M30 8JS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-04-05
LOCAL AUTHORITY E08000006
CONSTITUENCY E14001598
COUNTY
LODGEMENT DATE 2016-04-11
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 58
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 227
ENERGY CONSUMPTION POTENTIAL 144
CO2 EMISSIONS CURRENT 4.7
CO2 EMISS CURR PER FLOOR AREA 40
CO2 EMISSIONS POTENTIAL 3.0
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 69
HEATING COST CURRENT 862
HEATING COST POTENTIAL 750
HOT WATER COST CURRENT 116
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 117
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 64
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 64% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.47
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22, Botany Road, Eccles
LOCAL AUTHORITY LABEL Salford
CONSTITUENCY LABEL Worsley and Eccles
POSTTOWN MANCHESTER
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2016-04-11 11:45:55
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 47
LOW ENERGY FIXED LIGHT COUNT 30
UPRN 100011348064
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000002
Address display
Nation ew