Energy Performance Certificate

119, Rosemary Crescent West, WV4 5AN

EPC Report

Energy rating

Current: 16 G | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 G Current: 16 G 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 29 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 Current: 29 63 Potential: 63
Field Value
LMK KEY 0947-2890-7488-9293-0301
ADDRESS1 119, Rosemary Crescent West
ADDRESS2
ADDRESS3
POSTCODE WV4 5AN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 16
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-08-10
LOCAL AUTHORITY E08000031
CONSTITUENCY E14001596
COUNTY
LODGEMENT DATE 2017-09-02
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 29
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 531
ENERGY CONSUMPTION POTENTIAL 224
CO2 EMISSIONS CURRENT 9.4
CO2 EMISS CURR PER FLOOR AREA 90
CO2 EMISSIONS POTENTIAL 4.0
LIGHTING COST CURRENT 123
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 2381
HEATING COST POTENTIAL 652
HOT WATER COST CURRENT 354
HOT WATER COST POTENTIAL 105
TOTAL FLOOR AREA 105
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 95
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 14
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 14% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.56
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 119, Rosemary Crescent West
LOCAL AUTHORITY LABEL Wolverhampton
CONSTITUENCY LABEL Wolverhampton West
POSTTOWN WOLVERHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2017-09-02 12:43:04
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100071190743
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000005
Address display
Nation ew