Energy Performance Certificate

44, Frances Road, Lozells, B19 1SA

EPC Report

Energy rating

Current: 1 G | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 12 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 12 Current: 12 69 Potential: 69
Field Value
LMK KEY 0945-2848-7246-9096-8755
ADDRESS1 44, Frances Road
ADDRESS2 Lozells
ADDRESS3
POSTCODE B19 1SA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-04-18
LOCAL AUTHORITY E08000025
CONSTITUENCY E14001098
COUNTY
LODGEMENT DATE 2016-04-18
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 12
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 637
ENERGY CONSUMPTION POTENTIAL 146
CO2 EMISSIONS CURRENT 24
CO2 EMISS CURR PER FLOOR AREA 108
CO2 EMISSIONS POTENTIAL 5.8
LIGHTING COST CURRENT 200
LIGHTING COST POTENTIAL 100
HEATING COST CURRENT 6867
HEATING COST POTENTIAL 1253
HOT WATER COST CURRENT 117
HOT WATER COST POTENTIAL 118
TOTAL FLOOR AREA 224
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 44, Frances Road, Lozells
LOCAL AUTHORITY LABEL Birmingham
CONSTITUENCY LABEL Birmingham Perry Barr
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-04-18 20:27:32
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100070371862
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000005
Address display
Nation ew