Energy Performance Certificate

5, Bolwell Close, Twyford, RG10 0LN

EPC Report

Energy rating

Current: 65 D | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 64 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 95 Potential: 95
Field Value
LMK KEY 0942-2848-6853-9822-0885
ADDRESS1 5, Bolwell Close
ADDRESS2 Twyford
ADDRESS3
POSTCODE RG10 0LN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-05-28
LOCAL AUTHORITY E06000041
CONSTITUENCY E14001593
COUNTY
LODGEMENT DATE 2012-05-28
TRANSACTION TYPE rental (private)
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 234
ENERGY CONSUMPTION POTENTIAL 23
CO2 EMISSIONS CURRENT 2.7
CO2 EMISS CURR PER FLOOR AREA 45
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 65
LIGHTING COST POTENTIAL 34
HEATING COST CURRENT 339
HEATING COST POTENTIAL 250
HOT WATER COST CURRENT 188
HOT WATER COST POTENTIAL 74
TOTAL FLOOR AREA 60
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 20
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 11
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Warm air, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 11% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Bolwell Close, Twyford
LOCAL AUTHORITY LABEL Wokingham
CONSTITUENCY LABEL Wokingham
POSTTOWN READING
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2012-05-28 13:55:40
TENURE
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 14058602
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000008
Address display
Nation ew