Energy Performance Certificate

1d, Riley Road, EN3 5QB

EPC Report

Energy rating

Current: 87 B | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 87 B Current: 87 B 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 88 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 Current: 88 93 Potential: 93
Field Value
LMK KEY 0938-9063-7352-6380-3244
ADDRESS1 1d, Riley Road
ADDRESS2
ADDRESS3
POSTCODE EN3 5QB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 87
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2020-02-07
LOCAL AUTHORITY E09000010
CONSTITUENCY E14001225
COUNTY
LODGEMENT DATE 2020-02-07
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 88
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 54
ENERGY CONSUMPTION POTENTIAL 26
CO2 EMISSIONS CURRENT 0.9
CO2 EMISS CURR PER FLOOR AREA 9
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 76
LIGHTING COST POTENTIAL 76
HEATING COST CURRENT 323
HEATING COST POTENTIAL 326
HOT WATER COST CURRENT 333
HOT WATER COST POTENTIAL 164
TOTAL FLOOR AREA 97
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Average thermal transmittance 0.12 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.17 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.17 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric underfloor heating
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 1d, Riley Road
LOCAL AUTHORITY LABEL Enfield
CONSTITUENCY LABEL Enfield North
POSTTOWN ENFIELD
CONSTRUCTION AGE BAND 2019
LODGEMENT DATETIME 2020-02-07 14:57:53
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 207023653
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2020.csv
COUNTRY England
REGION E12000007
Address display
Nation ew