Energy Performance Certificate
474 RADFORD ROAD, COVENTRY, CV6 3AE
Energy rating
Current: 49 E | Potential: 61 D
Environmental impact (CO₂)
Current: 45
| Potential: 55
| Field | Value |
|---|---|
| LMK KEY | 0937-1007-1304-9969-0200 |
| ADDRESS1 | 474 RADFORD ROAD |
| ADDRESS2 | COVENTRY |
| ADDRESS3 | — |
| POSTCODE | CV6 3AE |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY RATING | D |
| CURRENT ENERGY EFFICIENCY | 49 |
| POTENTIAL ENERGY EFFICIENCY | 61 |
| PROPERTY TYPE | House |
| BUILT FORM | Mid-Terrace |
| INSPECTION DATE | 2021-04-07 |
| LOCAL AUTHORITY | E08000026 |
| CONSTITUENCY | E14001181 |
| COUNTY | — |
| LODGEMENT DATE | 2021-04-07 |
| TRANSACTION TYPE | None of the above |
| ENVIRONMENT IMPACT CURRENT | 45 |
| ENVIRONMENT IMPACT POTENTIAL | 55 |
| ENERGY CONSUMPTION CURRENT | 363 |
| ENERGY CONSUMPTION POTENTIAL | 282 |
| CO2 EMISSIONS CURRENT | 5.0 |
| CO2 EMISS CURR PER FLOOR AREA | 64 |
| CO2 EMISSIONS POTENTIAL | 4.0 |
| LIGHTING COST CURRENT | 87 |
| LIGHTING COST POTENTIAL | 87 |
| HEATING COST CURRENT | 1032 |
| HEATING COST POTENTIAL | 1032 |
| HOT WATER COST CURRENT | 89 |
| HOT WATER COST POTENTIAL | 61 |
| TOTAL FLOOR AREA | 79 |
| ENERGY TARIFF | standard tariff |
| MAINS GAS FLAG | — |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Programmer, room thermostat and TRVs |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | — |
| GLAZED AREA | — |
| EXTENSION COUNT | — |
| NUMBER HABITABLE ROOMS | — |
| NUMBER HEATED ROOMS | — |
| LOW ENERGY LIGHTING | 75 |
| NUMBER OPEN FIREPLACES | 1 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Average thermal transmittance 1.20 W/m²K |
| FLOOR ENERGY EFF | Very Poor |
| FLOOR ENV EFF | Very Poor |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Average thermal transmittance 2.10 W/m²K |
| WALLS ENERGY EFF | Very Poor |
| WALLS ENV EFF | Very Poor |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Average thermal transmittance 0.6 W/m²K |
| ROOF ENERGY EFF | Poor |
| ROOF ENV EFF | Poor |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 75% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | Gas: mains gas |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.44 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | — |
| MECHANICAL VENTILATION | — |
| ADDRESS | 474 RADFORD ROAD, COVENTRY |
| LOCAL AUTHORITY LABEL | Coventry |
| CONSTITUENCY LABEL | Coventry North West |
| POSTTOWN | COVENTRY |
| CONSTRUCTION AGE BAND | 2021 |
| LODGEMENT DATETIME | 2021-04-07 10:33:21 |
| TENURE | rented (social) |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 6 |
| UPRN | 100070691746 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 3 |
| Source file | certificates-2021.csv |
| COUNTRY | England |
| REGION | E12000005 |
| Address display | — |
| Nation | ew |