Energy Performance Certificate

23 Birch Crescent, Cefn Hengoed, CF82 7LJ

EPC Report

Energy rating

Current: 76 C | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 75 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 89 Potential: 89
Field Value
LMK KEY 0934-0204-0307-2401-3804
ADDRESS1 23 Birch Crescent
ADDRESS2 Cefn Hengoed
ADDRESS3
POSTCODE CF82 7LJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2023-07-14
LOCAL AUTHORITY W06000018
CONSTITUENCY W07000088
COUNTY
LODGEMENT DATE 2023-07-14
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 75
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 170
ENERGY CONSUMPTION POTENTIAL 69
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 30
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 63
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 384
HEATING COST POTENTIAL 355
HOT WATER COST CURRENT 74
HOT WATER COST POTENTIAL 49
TOTAL FLOOR AREA 75
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23 Birch Crescent, Cefn Hengoed
LOCAL AUTHORITY LABEL Caerphilly
CONSTITUENCY LABEL Caerphilly
POSTTOWN HENGOED
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2023-07-14 08:04:14
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 43020481
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew