Energy Performance Certificate

155, Baxter Avenue, DY10 2EX

EPC Report

Energy rating

Current: 47 E | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 E Current: 47 E 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 38 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 Current: 38 74 Potential: 74
Field Value
LMK KEY 0920-2889-7967-9426-9495
ADDRESS1 155, Baxter Avenue
ADDRESS2
ADDRESS3
POSTCODE DY10 2EX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 47
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2016-06-21
LOCAL AUTHORITY E07000239
CONSTITUENCY E14001601
COUNTY
LODGEMENT DATE 2016-06-24
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 38
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 362
ENERGY CONSUMPTION POTENTIAL 132
CO2 EMISSIONS CURRENT 8.4
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 112
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 1589
HEATING COST POTENTIAL 774
HOT WATER COST CURRENT 123
HOT WATER COST POTENTIAL 84
TOTAL FLOOR AREA 132
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS TRVs and bypass
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 46
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 46% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 155, Baxter Avenue
LOCAL AUTHORITY LABEL Wyre Forest
CONSTITUENCY LABEL Wyre Forest
POSTTOWN KIDDERMINSTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2016-06-24 14:48:07
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100120721875
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000005
Address display
Nation ew