Energy Performance Certificate

33, Vicarage Drive, BN20 8AP

EPC Report

Energy rating

Current: 70 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 65 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 78 Potential: 78
Field Value
LMK KEY 0920-2803-7065-9401-3391
ADDRESS1 33, Vicarage Drive
ADDRESS2
ADDRESS3
POSTCODE BN20 8AP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2019-06-07
LOCAL AUTHORITY E07000061
CONSTITUENCY E14001219
COUNTY
LODGEMENT DATE 2019-06-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 191
ENERGY CONSUMPTION POTENTIAL 119
CO2 EMISSIONS CURRENT 5.9
CO2 EMISS CURR PER FLOOR AREA 30
CO2 EMISSIONS POTENTIAL 3.6
LIGHTING COST CURRENT 101
LIGHTING COST POTENTIAL 103
HEATING COST CURRENT 1419
HEATING COST POTENTIAL 1017
HOT WATER COST CURRENT 147
HOT WATER COST POTENTIAL 83
TOTAL FLOOR AREA 196
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 20
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.91
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 33, Vicarage Drive
LOCAL AUTHORITY LABEL Eastbourne
CONSTITUENCY LABEL Eastbourne
POSTTOWN EASTBOURNE
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2019-06-07 18:09:43
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 24
LOW ENERGY FIXED LIGHT COUNT 24
UPRN 100060023779
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew