Energy Performance Certificate

49 Stapleton Drive, Fordbridge, B37 5LQ

EPC Report

Energy rating

Current: 50 E | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 E Current: 50 E 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 55 | Potential: 62
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 62 Potential: 62
Field Value
LMK KEY 0919-8012-6002-0909-7496
ADDRESS1 49 Stapleton Drive
ADDRESS2 Fordbridge
ADDRESS3
POSTCODE B37 5LQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 50
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2022-11-01
LOCAL AUTHORITY E08000029
CONSTITUENCY E14001358
COUNTY
LODGEMENT DATE 2022-11-01
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 62
ENERGY CONSUMPTION CURRENT 387
ENERGY CONSUMPTION POTENTIAL 331
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 65
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 45
LIGHTING COST POTENTIAL 49
HEATING COST CURRENT 759
HEATING COST POTENTIAL 328
HOT WATER COST CURRENT 358
HOT WATER COST POTENTIAL 180
TOTAL FLOOR AREA 45
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 49 Stapleton Drive, Fordbridge
LOCAL AUTHORITY LABEL Solihull
CONSTITUENCY LABEL Meriden and Solihull East
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2022-11-01 22:55:51
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100070968049
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000005
Address display
Nation ew