Energy Performance Certificate

40, Worting Road, RG21 8TW

EPC Report

Energy rating

Current: 46 E | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 38 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 Current: 38 71 Potential: 71
Field Value
LMK KEY 0916-2841-7072-9495-5581
ADDRESS1 40, Worting Road
ADDRESS2
ADDRESS3
POSTCODE RG21 8TW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-03-19
LOCAL AUTHORITY E07000084
CONSTITUENCY E14001078
COUNTY
LODGEMENT DATE 2015-03-19
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 38
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 344
ENERGY CONSUMPTION POTENTIAL 134
CO2 EMISSIONS CURRENT 8.7
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 120
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 1603
HEATING COST POTENTIAL 853
HOT WATER COST CURRENT 112
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 137
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 58
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 35
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 35% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.56
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 40, Worting Road
LOCAL AUTHORITY LABEL Basingstoke and Deane
CONSTITUENCY LABEL Basingstoke
POSTTOWN BASINGSTOKE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-03-19 17:36:47
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100060249493
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display
Nation ew