Energy Performance Certificate

171, Mottram Road, SK14 2NX

EPC Report

Energy rating

Current: 51 E | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 48 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 93 Potential: 93
Field Value
LMK KEY 0910-2805-7264-9427-6331
ADDRESS1 171, Mottram Road
ADDRESS2
ADDRESS3
POSTCODE SK14 2NX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-06-25
LOCAL AUTHORITY E08000008
CONSTITUENCY E14001515
COUNTY
LODGEMENT DATE 2013-06-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 361
ENERGY CONSUMPTION POTENTIAL 50
CO2 EMISSIONS CURRENT 4.4
CO2 EMISS CURR PER FLOOR AREA 69
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 69
LIGHTING COST POTENTIAL 38
HEATING COST CURRENT 531
HEATING COST POTENTIAL 317
HOT WATER COST CURRENT 321
HOT WATER COST POTENTIAL 65
TOTAL FLOOR AREA 63
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 25 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 171, Mottram Road
LOCAL AUTHORITY LABEL Tameside
CONSTITUENCY LABEL Stalybridge and Hyde
POSTTOWN HYDE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-06-25 17:17:38
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100011577308
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display
Nation ew