Energy Performance Certificate

58 Elizabeth Court, Queen Street, CT6 5PD

EPC Report

Energy rating

Current: 25 F | Potential: 48 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 F Current: 25 F 48 E Potential: 48 E

Environmental impact (CO₂)

Current: 14 | Potential: 25
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 14 Current: 14 25 Potential: 25
Field Value
LMK KEY 0908-2822-7762-9505-9015
ADDRESS1 58 Elizabeth Court
ADDRESS2 Queen Street
ADDRESS3
POSTCODE CT6 5PD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 25
POTENTIAL ENERGY EFFICIENCY 48
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-06-02
LOCAL AUTHORITY E07000106
CONSTITUENCY E14001282
COUNTY
LODGEMENT DATE 2015-10-03
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 14
ENVIRONMENT IMPACT POTENTIAL 25
ENERGY CONSUMPTION CURRENT 1194
ENERGY CONSUMPTION POTENTIAL 919
CO2 EMISSIONS CURRENT 6.0
CO2 EMISS CURR PER FLOOR AREA 202
CO2 EMISSIONS POTENTIAL 4.6
LIGHTING COST CURRENT 53
LIGHTING COST POTENTIAL 27
HEATING COST CURRENT 801
HEATING COST POTENTIAL 558
HOT WATER COST CURRENT 204
HOT WATER COST POTENTIAL 107
TOTAL FLOOR AREA 30
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Much Less Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 58 Elizabeth Court, Queen Street
LOCAL AUTHORITY LABEL Canterbury
CONSTITUENCY LABEL Herne Bay and Sandwich
POSTTOWN HERNE BAY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-10-03 07:14:29
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100062054516
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display
Nation ew