Energy Performance Certificate

The Sheiling, Toft, Dunchurch, CV22 6NR

EPC Report

Energy rating

Current: 52 E | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 44 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 Current: 44 67 Potential: 67
Field Value
LMK KEY 0902-2857-7523-9297-8341
ADDRESS1 The Sheiling
ADDRESS2 Toft
ADDRESS3 Dunchurch
POSTCODE CV22 6NR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-02-13
LOCAL AUTHORITY E07000220
CONSTITUENCY E14001309
COUNTY
LODGEMENT DATE 2013-02-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 44
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 254
ENERGY CONSUMPTION POTENTIAL 143
CO2 EMISSIONS CURRENT 13
CO2 EMISS CURR PER FLOOR AREA 49
CO2 EMISSIONS POTENTIAL 7.6
LIGHTING COST CURRENT 116
LIGHTING COST POTENTIAL 118
HEATING COST CURRENT 2280
HEATING COST POTENTIAL 1419
HOT WATER COST CURRENT 115
HOT WATER COST POTENTIAL 116
TOTAL FLOOR AREA 272
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 45
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 77
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 77% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS The Sheiling, Toft, Dunchurch
LOCAL AUTHORITY LABEL Rugby
CONSTITUENCY LABEL Kenilworth and Southam
POSTTOWN RUGBY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2013-02-19 10:21:30
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 31
LOW ENERGY FIXED LIGHT COUNT 24
UPRN 10010509244
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000005
Address display
Nation ew