Energy Performance Certificate

35, Henley Road, LS13 3AJ

EPC Report

Energy rating

Current: 30 F | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 F Current: 30 F 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 38 | Potential: 96
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 Current: 38 96 Potential: 96
Field Value
LMK KEY 0901-2810-7013-9492-8135
ADDRESS1 35, Henley Road
ADDRESS2
ADDRESS3
POSTCODE LS13 3AJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 30
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-09-10
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001325
COUNTY
LODGEMENT DATE 2012-09-10
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 38
ENVIRONMENT IMPACT POTENTIAL 96
ENERGY CONSUMPTION CURRENT 523
ENERGY CONSUMPTION POTENTIAL 24
CO2 EMISSIONS CURRENT 5.0
CO2 EMISS CURR PER FLOOR AREA 93
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 65
LIGHTING COST POTENTIAL 32
HEATING COST CURRENT 786
HEATING COST POTENTIAL 277
HOT WATER COST CURRENT 410
HOT WATER COST POTENTIAL 50
TOTAL FLOOR AREA 54
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 65
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL To be used only when there is no heating/hot-water system
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 35, Henley Road
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds West and Pudsey
POSTTOWN LEEDS
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2012-09-10 11:05:37
TENURE
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 72096759
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000003
Address display
Nation ew