Energy Performance Certificate

1, Sunnyside, Coulby Newham, TS8 0RA

EPC Report

Energy rating

Current: 66 D | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 D Current: 66 D 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 66 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 Current: 66 88 Potential: 88
Field Value
LMK KEY 0899-2891-6066-9722-2125
ADDRESS1 1, Sunnyside
ADDRESS2 Coulby Newham
ADDRESS3
POSTCODE TS8 0RA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 66
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2012-06-29
LOCAL AUTHORITY E06000002
CONSTITUENCY E14001368
COUNTY
LODGEMENT DATE 2012-07-02
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 66
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 218
ENERGY CONSUMPTION POTENTIAL 84
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 41
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 58
LIGHTING COST POTENTIAL 43
HEATING COST CURRENT 566
HEATING COST POTENTIAL 413
HOT WATER COST CURRENT 84
HOT WATER COST POTENTIAL 61
TOTAL FLOOR AREA 76
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 22
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 64
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 64% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Sunnyside, Coulby Newham
LOCAL AUTHORITY LABEL Middlesbrough
CONSTITUENCY LABEL Middlesbrough South and East Cleveland
POSTTOWN MIDDLESBROUGH
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2012-07-02 00:51:12
TENURE
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100110137342
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000001
Address display
Nation ew