Energy Performance Certificate

8, Copper Close, Woolsery, EX39 5TR

EPC Report

Energy rating

Current: 54 E | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 47 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 81 Potential: 81
Field Value
LMK KEY 0897-2836-6592-9395-3095
ADDRESS1 8, Copper Close
ADDRESS2 Woolsery
ADDRESS3
POSTCODE EX39 5TR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2015-01-16
LOCAL AUTHORITY E07000046
CONSTITUENCY E14001552
COUNTY
LODGEMENT DATE 2015-01-16
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 298
ENERGY CONSUMPTION POTENTIAL 39
CO2 EMISSIONS CURRENT 3.3
CO2 EMISS CURR PER FLOOR AREA 77
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 46
LIGHTING COST POTENTIAL 33
HEATING COST CURRENT 405
HEATING COST POTENTIAL 286
HOT WATER COST CURRENT 216
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 43
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8, Copper Close, Woolsery
LOCAL AUTHORITY LABEL Torridge
CONSTITUENCY LABEL Torridge and Tavistock
POSTTOWN BIDEFORD
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2015-01-16 19:59:21
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100040373767
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000009
Address display
Nation ew