Energy Performance Certificate

5, Archibald Road, RM3 0RD

EPC Report

Energy rating

Current: 43 E | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 E Current: 43 E 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 40 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 83 Potential: 83
Field Value
LMK KEY 0895-2804-6864-9192-4161
ADDRESS1 5, Archibald Road
ADDRESS2
ADDRESS3
POSTCODE RM3 0RD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 43
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2012-06-14
LOCAL AUTHORITY E09000016
CONSTITUENCY E14001292
COUNTY
LODGEMENT DATE 2012-06-14
TRANSACTION TYPE rental (private)
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 400
ENERGY CONSUMPTION POTENTIAL 97
CO2 EMISSIONS CURRENT 5.5
CO2 EMISS CURR PER FLOOR AREA 77
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 57
LIGHTING COST POTENTIAL 40
HEATING COST CURRENT 865
HEATING COST POTENTIAL 422
HOT WATER COST CURRENT 146
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 71
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 53
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.55
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Archibald Road
LOCAL AUTHORITY LABEL Havering
CONSTITUENCY LABEL Hornchurch and Upminster
POSTTOWN ROMFORD
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2012-06-14 21:28:57
TENURE
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100021359013
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000007
Address display
Nation ew