Energy Performance Certificate

5, Buckhurst Close, RH1 2AQ

EPC Report

Energy rating

Current: 65 D | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 59 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 86 Potential: 86
Field Value
LMK KEY 0888-3045-7216-6141-9964
ADDRESS1 5, Buckhurst Close
ADDRESS2
ADDRESS3
POSTCODE RH1 2AQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-06-08
LOCAL AUTHORITY E07000211
CONSTITUENCY E14001442
COUNTY
LODGEMENT DATE 2019-06-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 244
ENERGY CONSUMPTION POTENTIAL 75
CO2 EMISSIONS CURRENT 3.9
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 64
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 514
HEATING COST POTENTIAL 391
HOT WATER COST CURRENT 250
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Buckhurst Close
LOCAL AUTHORITY LABEL Reigate and Banstead
CONSTITUENCY LABEL Reigate
POSTTOWN REDHILL
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2019-06-08 19:36:54
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 68132957
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew