Energy Performance Certificate

157 Meadow Way, Jaywick, CO15 2HA

EPC Report

Energy rating

Current: 61 D | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 42 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 75 Potential: 75
Field Value
LMK KEY 0885-1909-0202-1869-0200
ADDRESS1 157 Meadow Way
ADDRESS2 Jaywick
ADDRESS3
POSTCODE CO15 2HA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2021-12-08
LOCAL AUTHORITY E07000076
CONSTITUENCY E14001174
COUNTY
LODGEMENT DATE 2021-12-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 545
ENERGY CONSUMPTION POTENTIAL 186
CO2 EMISSIONS CURRENT 3.7
CO2 EMISS CURR PER FLOOR AREA 92
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 41
LIGHTING COST POTENTIAL 41
HEATING COST CURRENT 596
HEATING COST POTENTIAL 353
HOT WATER COST CURRENT 158
HOT WATER COST POTENTIAL 87
TOTAL FLOOR AREA 40
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 157 Meadow Way, Jaywick
LOCAL AUTHORITY LABEL Tendring
CONSTITUENCY LABEL Clacton
POSTTOWN CLACTON-ON-SEA
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2021-12-08 14:06:57
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100090610505
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000006
Address display
Nation ew